How Fit Testing Saves Hearing, Ensures Readiness

Image of How Fit Testing Saves Hearing, Ensures Readiness. How Fit Testing Saves Hearing, Ensures Readiness

The Department of Defense will soon require fit testing for hearing protection to guard against future hearing loss and maintain fitness for duty.

Without hearing protection, service members and DOD civilians are at risk of permanent hearing loss when exposed to high noise levels like firearms, explosives, vehicle noise, and “continuous hazardous noise whether the exposure occurs on- or off-duty,” according to Theresa Schulz, the Defense Health Agency Hearing Center of Excellence chief of the prevention and surveillance section and a doctor of audiology. The center is a branch of the DHA Research and Engineering Directorate.

On the positive side, an HCE report for FY 2021 on military hearing conservation found military hearing losses to be at stable levels.

“Although it is stable, it’s not improving,” said U.S. Army Lt. Col. Michael Murphy, the U.S. Army audiology liaison at HCE and chief of the studies and analysis section. Hearing loss and tinnitus remain the number one and number three disability claims for the Department of Veterans Affairs, respectively, he said.

What a Fit Test Measures

“Referrals for a hearing protector fit test are generated from the hearing conservation clinic at your local military hospital or clinic or other hearing professionals embedded in occupational health, industrial hygiene, or safety,” Murphy said.

Your personal attenuation level, or PAR, “is an objective measure of total hearing protection provided by your hearing protector. The PAR may fluctuate depending on the placement of the hearing protector, such as depth in your ear canal or other characteristics specific to your ear,” he said.

“Hearing protectors with a PAR that reduces the noise below 85 decibels of continuous sound pressure level and below 140 decibels of peak sound pressure can mitigate the risk from hazardous noise,” Murphy explained.

Importance of Fit Testing

There are potential issues with current hearing protective device standards that fit testing can address, said Dr. Doug Brungart, the senior hearing scientist at the National Military Audiology and Speech Pathology Center at Walter Reed National Military Medical Center in Bethesda, Maryland, who has a doctorate of electrical engineering.

According to Brungart, current standards for selecting and issuing hearing protection are designed to ensure roughly 95% of all individuals who use a device without fit-test verification are able to obtain enough noise reduction to prevent them from exceeding their maximum allowable daily noise exposure.

However, some users may have more protection than needed, which can make it difficult to maintain awareness of voices, alarms, and other important sounds in the environment. There may also be some extremely noisy environments where a substantial number of service members do not receive as much protection as they require, Brungart explained.

By comparison, “fit testing can tell us the true attenuation an individual is getting from a hearing protector, rather than forcing us to rely on selecting a protector with much more noise reduction than is needed to obtain a wide margin of safety to protect listeners who have a relatively poor fit with the device,” Brungart said.

Updated DOD Fit-Testing Policy Forthcoming

A revised DOD Instruction 6055.12 will update the August 2019 policy and address the Centers for Disease Control and Prevention’s position that “fit testing is an effective, practical, and essential tool for preventing occupational hearing loss.”

Under the revised instruction, all DOD personnel enrolled in their service’s hearing conservation program and exposed to high noise levels, at or above 95 decibels over an 8-hour average, will get a hearing protector fit test when they enroll in the hearing conservation program. Testing happens before initial duty in hazardous noise areas or as soon as possible after employment begins.

DOD personnel exposed to continuous and intermittent noise at or above 85 decibels as measured in this 8-hour average or impulse noise sound pressure levels of 140 decibels or greater for at least one day per year must be enrolled in a hearing conservation program.

The Defense Centers for Public Health-Aberdeen said hearing conservation and readiness programs “reduce the impact of hazardous and occupational noise-exposures to maintain fitness for duty and protect mission readiness and situational awareness in training, garrison, and deployed environments.” All U.S. Army soldiers are already enrolled in hearing conservation programs.

Additional criteria for hearing protection fit testing will go into effect with the new DOD instruction, currently expected for release by December 2023.

The instruction addresses the minimum requirements for hearing protector fit testing in the DOD, HCE said. Each service may have more stringent requirements for hearing protector fit testing that better meet the needs of their hearing conservation program, HCE explained.

‘Last Line of Defense’

Schulz shared advice about hearing protectors, which she called “the last line of defense from noise-induced hearing loss,” including:

  • Find hearing protectors that work for you.
  • Ensure you fit them appropriately.
  • Use them whenever you are exposed to hazardous noise.
  • Fit testing is a powerful training tool to ensure wearers know “what right feels like.”

“There are hearing protector solutions that simultaneously protect you from hazardous noise and safely allow you to identify warning signals and maintain communication,” Murphy noted.

“Sudden changes to your hearing noted from hazardous noise, such as firing your weapon, may be indicative of permanent hearing loss,” Murphy said. “See your hearing conservation clinic or hearing professional immediately for medical management if your symptoms do not resolve within 36 hours.”

Additional advice from the Walter Reed National Military Audiology and Speech Pathology Center includes:

  • Make sure other personal protective equipment doesn’t interfere with the ability to properly fit hearing protection, such as protective eyewear, that can result in an air leak for earmuff protectors.
  • Hearing protectors are not a one-size-fits-all solution. If there are issues with a particular model, try a different solution, so long as the noise reduction levels are appropriate for the environment.

“Good hearing is a key to mission success—increasing operational efficacy and survivability in combat, increasing mission and training effectiveness and, maintaining quality of life,” Schulz said. “What sounds are important to you? How would you feel if you could no longer hear them? How would that loss affect your quality of life and mental health?”

You also may be interested in...

Report
Jan 1, 2014

MSMR Vol. 21 No. 4 - April 2014

.PDF | 489.25 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Absolute and relative morbidity burdens attributable to various illnesses and injuries, U.S. Armed Forces, 2013; Hospitalizations among members of the active component, U.S. Armed Forces, 2013; Ambulatory ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 12 - December 2014

.PDF | 756.31 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Development and implementation of a cohort review for latent tuberculosis infection; Brief report: number of tuberculosis tests and diagnoses of latent tuberculosis infection in active component service ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 1 - January 2014

.PDF | 615.15 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Images in health surveillance: dengue and chikungunya virus vectors and prevention; Surveillance snapshot: self-reported malaria prophylaxis compliance among service members with diagnosed malaria, 2008-2013; ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 11 - November 2014

.PDF | 549.40 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Transfusion-transmissible infections among U.S. military recipients of emergently transfused blood products, June 2006-December 2012; Evaluation of extragenital screening for gonorrhea and chlamydia in HIV ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 2 - February 2014

.PDF | 372.58 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Surveillance snapshot: male infertility, active component, U.S. Armed Forces, 2000-2012; Urinary tract infections, active component, U.S. Armed Forces, 2000-2013; Human T-lymphotropic virus infections in ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 10 - October 2014

.PDF | 617.63 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Suicides and suicide attempts among active component members of the U.S. Armed Forces, 2010-2012: methods of self-harm vary by major geographic region of assignment; Risk of type II diabetes and hypertension ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 5 - May 2014

.PDF | 531.20 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Numbers and proportions of U.S. military members in treatment for mental disorders over time, active component, January 2000-September 2013; U.S. Armed Forces air crew: incident illness and injury diagnoses ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 3 - March 2014

.PDF | 477.89 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Legionellosis in Military Health System beneficiaries, 1998-2013; Urinary tract infections during deployment, active component, U.S. Armed Forces, 2008-2013; Update: heat injuries, active component, U.S. ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 9 - September 2014

.PDF | 409.66 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Fractures among active component, recruit trainees, and deployed service members, U.S. Armed Forces, 2003-2012; Diagnoses of eating disorders among active component service members, U.S. Armed Forces, 2004 ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 7 - July 2014

.PDF | 634.01 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Sunburn among active component service members, U.S. Armed Forces, 2002-2013; Brief report: sunburn diagnoses while deployed in Southwest/Central Asia, active component, U.S. Armed Forces, 2008-2013; ...

Report
Jan 1, 2014

MSMR Vol. 21 No. 8 - August 2014

.PDF | 551.02 KB

A monthly publication of the Armed Forces Health Surveillance Branch. This issue of the peer-reviewed journal contains the following articles: Spread of vaccinia virus through shaving during military training, Joint Base San Antonio-Lackland, TX, June 2014; Gynecologic disorders diagnosed during deployment to Southwest/Central Asia, active component ...

Presentation
Nov 18, 2013

Decision Brief Obesity

.PDF | 299.78 KB

Decision briefing to the Defense Health Board on Obesity presented on Nov. 18, 2013